Purpose:
To find is their difference on AC/A ratio amount between heterophoria method,
distance gradient with concave lens method and near gradient with convex lens
method with respect to gender and age.
Method:
Data was collected on 50 myopic subject (10 males,40 females), there ages were
from 17-28 years old subdivided to three group ages. All subjects had near and
distance vision tested along with an orthoptics examination. Near heterophoria,
near with convex lenses heterophoria, distance heterophoria and distance with
concave lenses heterophoria were measured. the AC/A ratios by heterophoria
method considering to IPD measurement, gradient method with convex lenses for
near and gradient with concave lenses for distance were measured. The data were
analyzed using the Wilcoxon Signed Rank test to investigate the significant
different between heterophoria method, gradient with convex lenses for near and
gradient with concave lenses for distance.
Result:
Mean (±SD) AC/A ratio for near gradient was (2.24±0.29), distance gradient was
(1.50±0.32) and heterophoria method was (5.96±0.58). The heterophoria method
tended to give a higher value than gradient method and the near gradient method
gave a higher value than distance gradient method. comparison of all methods
with Wilcoxon signed rank test showed that there was a statistically
significant difference between the methods(P<0.001). the AC/A ratio did not
differ between genders and no significant association between ages.
Conclusion:
From this result there is significant different on measuring AC/A ratio between
heterophoria method, distance gradient method with concave lens and near
gradient method with convex lens; so, we should use all method when measured
it.